Capabilities
Several test procedures evaluate glazing performance in the medium and high/maximum security
institutional setting. Each one specifies the specimen size and condition, the opening size that
constitutes failure, the weapons used and the number of impacts and sequence of attacks using
those specified weapons. The test standard section provides a summary of the various test methods.
It is essential that the design professional has a full understanding of the complete test protocol.
Oldcastle Glass® Security Laminates for use in Forced-Entry Applications |
| |
Nominal |
|
Max |
|
| |
HPW-TP-0500 |
ASTM |
UL |
Thickness |
Wt. |
Size |
|
| Trade name |
Product# |
FE |
BR |
WMFL |
F1233 |
752 |
in. |
lbs/ft2 |
in. |
Assembly(1) |
| ArmorProtect® |
111000 |
|
|
|
1-body passage |
|
1/2 |
5.4 |
60 x 96 |
AGL |
| ArmorProtect® |
112000 |
|
|
|
1 |
|
3/4 |
7.2 |
60 x 96 |
AGL |
| ArmorProtect® |
113000 |
|
|
|
1 |
|
1 |
9.1 |
60 x 96 |
AGL |
| ArmorProtect® Plus |
121000 |
1 |
A(2) |
|
|
|
7/16 |
4.6 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
121100 |
1 |
A(2) |
|
|
|
9/16 |
5.4 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
121200 |
1 |
B(2) |
|
|
|
11/16 |
6.2 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
122000 |
2 |
B(2) |
3 |
|
|
13/16 |
6.4 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
123200 |
2 |
B(2) |
2 |
|
|
15/16 |
7.2 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
123000 |
3 |
B(2) |
3 |
|
|
3/4 |
6.3 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
123100 |
3 |
B(2) |
2 |
|
|
7/8 |
7.1 |
60 x 96 |
GCP |
| ArmorProtect® Plus |
124100 |
|
|
1(2) |
|
|
1-1/4 |
10.8 |
60 x 96 |
GCP |
| ArmorProtect® Max |
132000 |
2-step 14 |
A |
|
|
|
3/8 |
2.5 |
60 x 96 |
LPC |
| ArmorProtect® Max |
133000 |
3-step 16 |
A |
|
|
|
1/2 |
3.4 |
60 x 96 |
LPC |
| ArmorProtect® Max |
134000 |
4-step 38 |
B |
|
|
|
3/4 |
5.0 |
60 x 96 |
LPC |
| ArmorProtect® Max |
135000 |
5 |
B |
|
|
2 |
1 |
6.6 |
60 x 96 |
LPC |
| ArmorProtect® Max |
135100 |
5 |
C |
2 |
|
3 |
1-1/4 |
8.2 |
60 x 96 |
LPC |
| HP White Test Summary |
| HPW-TP-0500 |
| Forced-Entry |
Ballistics |
| Level 1: Steps 1-5 |
Level A: 38 Special |
| Level 2: Steps 1-15 |
Level B: 9 mm |
| Level 3: Steps 1-26 |
Level C: .44 Magnum |
| Level 4: Steps 1-39 |
Level D: 7.62 mm |
| Level 5: Steps 1-54 |
Level E: .30-06 AP |
|
| WMFL Test Summary |
| Level 3: 30 Minute |
| Level 2: 60 Minute |
Level 1: 60 Minute and 25 rounds .44
Magnum(3) |
|
| ASTM F1233 Test Summary |
| Forced-Entry |
| Class 1: Steps 1 |
| Class 2: Steps 1-7 |
| Class 3: Steps 1-16 |
| Class 4: Steps 1-27 |
| Class 5: Steps 1-41 |
| (1) |
GPglass-clad polycarbonate with exposed polycarbonate; GCPglass-clad polycarbonate; LPClaminated polycarbonate; AGLall-glass laminate. |
| (2) |
These products resisted bullet penetration. They are not designed to resist spalling. |
| (3) |
This is not a no-spall ballistics test. |
|